Inputs 
 Type of bridge 
 Bridge connection 
 Measuring unit 
 Input voltage range 
 Internal resolution 
 Bridge adjustment 
 Gain error at 25 °C 
 Temperature drift 
 Measurement rate 
 HW input filter 
 SW input filter 
  
 Input protection 
 LED indicator per 
  | 
6 strain gauge inputs 
 Strain gauge full and half bridges 120, 350, 700, 1000 OHM 
 4- and 6 -wire 
 mV/V, ?m/m 
 ±200 mV 
 eff. 21 bit 
 via configuration software, up to 50 % of input voltage
range 
 max. ±0.05 % of measured value 
 ±20 ppm/K 
 1, 2, 5, 10, 20, 50, 100, 200, 500 Hz and 1, 2, 5, 10 
kHz 
 Low-pass filter 3rd order, 5 kHz 
 Low pass, 6 th order Butterworth filter, range: 0.1 Hz to 2 kHz,
can be switched off 
 ±20 V pe rmanent, additional ESD protection 
 Bridge excitation on (green) / short - circuit (red) 
 |